| HT Italia HT9015 Technical Specifications | |
| Accuracy is calculated as [% rdg + (number of dgt) x resolution]. It is referred to the following reference conditions: 18°C ÷ 28°C (65°F ÷ 83°F) with RH < 75% | |
| ELECTRICAL SPECIFICATIONS | |
| DC Voltage (Autorange) | 600.0mV – 1000V |
| AC Voltage TRMS (Autorange) | 6.000V – 1000V |
| Resistance and Continuity test (Autorange) | 600.0Ω – 60.00MΩ |
| DC Current | 60.00A – 600.0A |
| AC TRMS Current | 60.00A – 600.0A |
| Capacitance (Autorange) | 40.00nF – 4000µF |
| Frequency with test leads (Autorange) | 99.99Hz – 60.00kHz |
| Frequency with jaws (Autorange) | 99.99Hz – 9.999kHz |
Take extreme care for the following conditions while measuring:
• Do not measure voltage or current in humid or wet environment.
• Do not use the meter in presence of explosive gas (material), combustible gas (material), steam or dust.
• Insulate yourself from the object to be tested.
• Do not touch exposed metal (conductive) parts such as test lead ends, sockets, fixing objects, circuits, etc.
• If you detect anomalies of testing end (metal part) and attachment of the meter such as breakages, deformations, foreign substances, no display, etc., do not take any measurement.
• Measuring voltage over 20V as it might cause human body electricity conduction.
| HT Italia HT9015 GENERAL SPECIFICATIONS | |
| Mechanical characteristics | |
| Dimensions (L x W x H) | 215 x 74 x 43mm ; 8 x 3 x 2 in |
| Weight (including battery) | 285g (10 ounces) |
| Max conductor size | 30mm (1in) |
| Supply | |
| Battery type | 1 battery 9V NEDA 1604 IEC 6F22 JIS 006P |
| Battery life | about 200 hours. |
| Auto power OFF | after 15 minutes of idleness (not disabled) |
| Display | |
| Characteristics | 4 LCD (max 6000 counts), decimal point, unit symbol indication, bargraph and backlight |
| Sample rate | 2 times/sec |
| Conversion mode | TRMS |
| Climatic conditions | |
| Reference temperature | 18°C ÷ 28°C (65°F ÷ 83°F) |
| Operating temperature | 5 ÷ 40 °C (41°F ÷ 104°F) |
| Operating humidity | <80%RH |
| Storage temperature | -20 ÷ 60 °C (-4°F ÷ 140°F) |
| Storage humidity | <80%RH |
| Reference Standards | |
| Comply with | IEC/EN 61010-1 |
| Insulation | double insulation |
| Pollution | Level 2 |
| For inside use, max height | 2000m |
| Installation category | CAT IV 600V, CAT III 1000V to ground |