General Specifications | |
DC Voltage range | 200.0mV – 600V |
DC Voltage range | 200.0mV – 600V |
Resistance range | 200.0Ω – 20.00MΩ |
Operating temperature | -5°C to 40°C, <80%HR |
Storage temperature | -10°C to 60°C, <70%HR |
Power supply | 2 x 1.5V alkaline batteries type AAA MN2400 LR03 AM4 |
Sizes | 163(L)x88(W)x48(H) mm |
Weight (included batteries) | 280g |
PRELIMINARY
- This instrument has been designed for use in environments of pollution degree 2
- It can be used for VOLTAGE measurements on installations of CAT III 1000V or CAT IV 600V
- This instrument is not suitable for AC voltage and current measurements of not sinusoidal signals
- Only the original test leads supplied along with the instrument guarantee compliance with the safety standards in force. They must be in a good conditions and, if necessary, replaced with identical ones
- Do not test nor connect to any circuit exceeding the specified overload protection.
- Do not take measurements under environmental conditions exceeding the limits indicated in § 6.1.1. and § 6.2.1 Make sure that batteries are correctly installed
- Before connecting the test probes to the installation make sure that the rotary selector is positioned on the right function
- Make sure that LCD and rotary selector indicate the same function