FLIR CM65 TRUE RMS 600A Solar Clamp Meter
With the FLIR CM65 TRUE RMS 600A Solar Clamp Meter, you can check AC output and inverter efficiency and then store readings to the internal memory. Share data wirelessly via METERLiNK® or monitor measurements live on a smartphone running the FLIR Tools® mobile app.
Solar system installers can trust the Flir CM65 as their go-to tool for accelerating and simplifying photovoltaic panel testing on new and existing solar panels.
The Flir CM65 is a rugged clamp meter designed to meet the challenges of solar installation, maintenance, and repair. This clamp meter comes with quick-connect MC4 test leads that improve the accuracy and safety of DC voltage measurements on solar panel strings and inverters.
ACCURACY FOR ELECTRICAL AND SOLAR APPLICATIONS
The precision testing capabilities you need to get the job done right the first time.
• Trust AC voltage and current measurements from inverters and mains are accurate with True RMS
• Eliminate errors from residual ghost voltage using LoZ (low impedance) mode
• Get sharp ±1.5% accuracy when taking AC and DC current readings
• Capture the smallest voltage fluctuations when calibrating equipment using the CM65’s millivolt function
TOOLS YOU NEED TO WORK FASTER & SMARTER
This full-featured clamp meter with solar industry standard connectors helps you pinpoint trouble fast.
• Reduce the time needed for live/dead testing with included MC4 test leads
• Gain quick insights with Data Hold, Min/Max readings, and relative mode to zero the meter
• Troubleshoot string connections and components with a Continuity test mode
• Measure resistance, frequency and temperature
• Easily clamp around wires with the generous jaw (30 mm) and ergonomic design
THE RIGHT TECH TO SIMPLIFY YOUR WORKFLOW
The Flir CM65 is packed with tools to help you validate testing, document readings, and share results
• Take measurements, document results, and then share them on the go
• Identify trends and anomalies by data logging directly to the internal memory
• View readings right on your mobile device using the CM65’s METERLiNK® and the FLIR Tools® Mobile app –on the roof, on the ground, or anywhere on a job site
FLIR CM65 Specifications:
AC Current | |
Range and Resolution | 60.00, 600.0 A |
Basic Accuracy | ±1.5% |
DC Current | |
Range and Resolution | 60.00, 600.0 A |
Basic Accuracy | ±1.5% |
AC Voltage | |
Range and Resolution | 60.00, 600.0, 1000 V |
Basic Accuracy | ±0.7% |
AC Voltage (Digital Low Pass Filter – VFD) | |
Range and Resolution | 600.0, 1000 V |
Basic Accuracy | ±1% |
LoZ Mode AC Voltage | |
Range and Resolution | 600.0, 1000 V |
Basic Accuracy | ±2.0% |
AC Voltage (mV Mode) | |
Range and Resolution | 60.00, 600.0 mV |
Basic Accuracy | ±1.0% |
DC Voltage | |
Range and Resolution | 60.00, 600.0, 1000 V |
Basic Accuracy | ±1% |
LoZ Mode DC Voltage | |
Range and Resolution | 60.00, 600.0, 1000 V |
Basic Accuracy | ±2.0% |
DCV (mV Mode) | |
Range and Resolution | 60.00, 600.0 mV |
Basic Accuracy | ±1% |
Frequency | |
Range and Resolution | 50.00 to 400.0 Hz (ACA) |
10.00 to 400.0 Hz (ACV) | |
10.00 to 500.0 Hz (ACV mV) | |
Basic Accuracy | ±1% |
Resistance | |
Range and Resolution | 600.0 k, 6.000 kΩ |
Basic Accuracy | ±1.0% |
Diode Test | |
Range and Resolution | 3.000 V |
Basic Accuracy | ±0.9% |
Temperature | |
Range and Resolution | -40 to 400°C |
Basic Accuracy | ±1% |
Continuity | |
Range and Resolution | <30 Ω, 2 kHz buzzer |
General Specifications | |
Display | 3⅚ digits, 6000 counts |
Memory | 8 GB internal memory |
Operating Temperature | 0 to 60°C |
Operating Relative Humidity | Maximum relative humidity 80% for temperature up to 88°F (31°C) decreasing linearly to 50% relative humidity at 122°F (50°C) |
Storage Temperature | -30 to 60°C <80% RH (with battery removed) |
Drop Test | 1 m |
IP Rating | IP40 |
Safety Category Rating | CAT IV-600 V, CAT III-1000 V |
Certifications and Compliances | UL, CE, FCC, RCM |
ROHS and WEEE compliant | |
Battery | 3 x AA |
Dimensions | 251 x 80 x 40 mm |
Weight | 300 g |