The FLIR DM166 Thermal Imaging Multimeter is a must-have tool for commercial electricians, industrial electricians, electronics, and HVAC technicians. Featuring Infrared Guided Measurement (IGM) that’s powered by a built-in 80 x 60 FLIR thermal imager, the DM166 visually guides you to the precise location of potential problems.
The FLIR 166 allows professionals to efficiently test and troubleshoot electrical, electro-mechanical, and heating, ventilation, and cooling (HVAC) systems.
It’s Infrared Guided Measurement (IGM) gives the added benefit of visualising heat and highlighting temperature anomalies on it’s built-in display. Whether facing cluttered wires, complex panels, or clogged condenser coils, IGM guides users without requiring any direct contact with the test site, increasing both speed and user safety.
• Diagnose faults with broad DMM test functions
• Troubleshoot easier with the unique combination of onboard thermal imaging and traditional DMM test functions
• Carefully measure voltage with integrated non-contact voltage detection
• Work with peace of mind knowing your meter has a CAT III-600V, CAT IV-300V safety rating
• Remove high-frequency noise that affects readings with the Variable Frequency Drive (VFD) measurement function
• Precisely measure resistance up to 60 MΩ, frequency up to 50 KHz, and capacitance up to 10,000 µF
The FLIR DM166 includes the essential measurement features you demand from a multimeter including True RMS AC/DC voltage and current, non-contact voltage detection, VFD mode, and more.
The FLIR DM166 is the most affordable multimeter with built-in thermal imaging available to date.
FLIR DM166 Thermal Imaging TRMS Multimeter Specifications:
| Thermal Imaging | ||
| IR Resolution | 60 × 80 pixels (4,800 pixels) | |
| Thermal Image Palettes | Rainbow, iron, gray scale | |
| Temperature Range | –10 to 150°C (14 to 302°F) | |
| Focus | Fixed | |
| Electrical Measurements | ||
| True RMS | ||
| Range | Basic Accuracy | |
| AC / DC Voltage | 600.0 V | ±0.7% / ±0.5% |
| AC / DC milliVolt | 600.0 mV | ±1% / ±0.5% |
| VFD AC Voltage | 600.0 V RMS | ±1.0% |
| AC / DC Amperage | 10.00 A | ±1.0% / ±0.7% |
| AC / DC milliAmp | 600.0 mA | ±1.0% / ±0.7% |
| AC / DC µAmp | 4000 µA | ±1.5% |
| Resistance | 600.0 Ω | ±0.3% |
| 600.0 kΩ | ±0.5% | |
| 6.000 MΩ | ±0.9% | |
| 60.00 MΩ | ±1.5% | |
| Capacitance* | 200.0 nF | ±1.5% |
| 200.0 µF | ±1.5% | |
| 2.000 mF | ±2.0% | |
| 10.00 mF | ±5.0% | |
| Diode Test | 3.000 V | ±0.9% |
| Frequency Range | 99.99 kHz | ± 1.0% |
| Continuity Check | Between 30 Ω and 480 Ω | |
| Thermocouple, Type K | –40 to 400°C DMM ± (1.0% + 1.5°C) | |
| Safety Category Rating | IEC 61010-1, CAT III-600V, CAT IV-300V | |
| IP Rating | IP40 | |
| Auto Power Off | Yes | |
| Drop Test | 3 metre | |
| Warranty | 10 years on product and detector. |