FULLTEST 3 is the Most Advanced Solution for a Complete Compliance with the Actual Guidelines
Multifunction Tester for safety of machinery IEC/EN60204-1:2016 and low voltage switchgears and controlgears IEC/EN61439-1-2:2011
IEC/EN60204-1:2016 Measuments:
Power Frequency Dielectric withstand voltage with test voltage of 1000VAC
Testing protection against indirect contact:
- Continuity of protective conductors with test current 200mA
- Automatic disconnection of the supply (RCD, MCB, Fuse)
- RCD tripping (RCD AC, A, B) up to 1A on TT Systems
- Magneto-thermal protections (MCB curve verificaiton on B, C, D, K) and fuses (gG, aM) on TN Systems
Insulation resistance measurement with test voltage of 500VDC
Discharging of residual voltage V<60V in 5sec/1sec
IEC/EN61439-1-2:2011 Measurements:
Clearances and Creepage distances:
- Dielectric withstand voltage with test voltage of up to 3400/5100VAC
Continuity of earth system and protective conductors ≥10A
Power Frequency Dielectric withstand voltage with test voltage of 1800VAC
Alternative power-frequency voltage test up to 5100VAC
Test on enclosures of insulating material:
- Dielectric Withstand voltage with test voltage up to 2835V
Discharging of residual voltage V<60V in 5sec/1sec
FULLTEST3 is designed to satisfy the requirements of the IEC/EN60204-1:2006 guideline (electrical equipment of industrial machines) and for the new series of prescriptions relative to the IEC/EN61439-1 guideline (Switchgear panels). This last guideline require, among other tests, the Dielectric tests with a test voltage up to 5100V!
FULLTEST3 Features:
- Continuity of protection conductors with 200mA
- Continuity of protection conductors with I>10A, V<12V AC
- Continuity of protection conductors with I>25A, V<12V AC
- Insulation Resistance with 100,250,500,1000VDC test voltage
- Withstanding test with test voltage programmable from 250V to 5100V AC
- Discharging time test on internal capacitance and on power supply plug
- Leakage/absorbed and power on the test socket
- Leakage current with external clamp (HT96U optional accessories)
- Test on RCDs type A, AC, B General, Selective, Delayed up to 1000mA
- Line/Loop impedance and Ipsc calculation
- Line/Loop impedance with high resolution (with IMP57 optional accessories)
- Test on MCB protection with curve B, C, D, K and Fuse type gG and aM
- Selection of length, cable type, insulation of cable, tripping time of protection device
- Global earth resistance without RCD tripping
- Phase sequence indication
- TFT display with touch-screen
- Programmable timer on tests
- Programmable thresholds on measurement
- Internal memory
- USB interface for PC connection
- USB interface for keyboard, printer and barcode reader connection
Test to Guidelines:
- CEI 64-8
- CEI 64-8/7
- CE MARK
- EMC 2014/30/EU
- EMC: IEC/EN61326
- EN50106
- IEC/EN60204-1
- IEC/EN60598-1
- IEC/EN61010-1
- IEC/EN61187
- IEC/EN61335-1
- IEC/EN61439-1
- IEC/EN61439-2
- IEC/EN61557-1
- IEC/EN61557-13
- IEC/EN61557-14
- IEC/EN61557-2
- IEC/EN61557-3
- IEC/EN61557-4
- IEC/EN61557-6
- IEC/EN61557-7
- LVD 2014/35/EU
- UNE20460
Standard Accessories:
- Australian Power cord
- Test cable red, 3 metre, 2 pcs
- Test cable blue, 3 metre
- Test cable green, 3 metre
- C2033X : Cable 3 wires with Shuko plug
- Cable with 5kV safety, 2 pcs
- Test lead CAT III, 3 pcs
- Test lead CAT II, 3 pcs
- Alligator clip, 3pcs
- TOPVIEW2007 : Windows software + USB cable C2007
- Carry bag for accessories
- ISO9000 calibration certificate
Optional Accessories:
- IMP57 : Accessory for high resolution Loop/Line Impedance
- HT96U : Rigid clamp 1-100-1000A AC, diameter 54mm