Leda Electronics Logo. Western  Australia's largest distributor of Test Instruments Leda Electronics Showing The Way
 
Clamp-On Meters > Model CL360
Yokogawa Test and Measurement Logo

Yokogawa Clamp-On Meter for AC Leakage Current Measurements

Model CL360
Clamp-On Tester for AC Leakage Current Measurements

Yokogawa Model CL360 Clamp Meter for AC Leakage Current Measurements

Yokogawa CL360 Features
 
bullet Leakage current measurement with current range from 200mA to 1000A.
bullet AC and DC output.
bullet 68mm in diameter of measurable conductor.
bullet Mean value display.
bullet Manual range switching.
bullet Approved for conformity to safety standards EN61010-1, EN61010-2-032 (CAT III 300V)     (CAT II 600V)
 
 
Yokogawa Model CL360 Specifications
 

Parameter

Reference

Accuracy

AC Current

  Wide (40Hz to 1kHz) 50/60Hz

200mA/2A/20A

1.0+2 (50/60Hz)

1.5+2

200mA/2A/20A

3.0+2 (40 to 1kHz)

 

200A

1.5+2 (50/60Hz)

2.0+2

200A

3.5+2 (40 to 1kHz)

 

1000A (0 to 500A)

1.5+2 (50/60Hz)

2.0+2

1000A (0 to 500A)

3.5+2 (40 to 1kHz)

 

1000A (501 to 1000A)

5.0     (50/60Hz)

5.5

1000A (501 to 1000A)

10.0   (40 to 1kHz)

 

 

AC Output

 

200mA/2A/20A (0 to 200mV)

2.0

2.0

200A (0 to 200mV)

2.5

2.5

1000A (0 to 50mV/0 to 500A)

3.0

3.0

1000A (50 to 100mV/501 to 1000A)

5.0

5.0



DC Output
 

 

200mA/2A/20A (0 to 200mV)

3.0

3.5

200A (0 to 200mV)

3.5

4.0

1000A (0 to 50mV/0 to 500A)

5.0

5.5

1000A (50 to 100mV/501 to 1000A)

7.0

7.5

 
At 23°C ±5°C, 75% RH or less
Accuracy: ±(% rdg + dgt) = ±(% readout + value of least significant digit)
 
 
Yokogawa Model CL360 General Specifications
 

Parameter

Specification

Method of detection

Mean value

Display

LCD (Digital display:1999 counts)

Response Time

Approx. 1 second

Range Switching

Manual range

Data Hold

On all ranges

Peak Hold

On all ranges

Ambient Temperature and Humidity

-10 to 50°C
80% RH or less (no condensation)

Temperature Coefficient

N/A

Influence of External Magnetic Field

15mA or less in proximity to a 10mm-dia conductor carrying 100Amps.

Influence of Conductor Position

2% or less

Influence of residual current

10mA or less in proximity to a 10mm-dia conductor carrying 100Amps.

Safety Standard

EN61010-1, EN61010-2-032 (CAT III 300V)

Circuit Voltage

600Vrms or less

Withstanding Voltage

3.7kV AC for one minute

Power Supply

6F22(006P)9V x 1 or 6LR61 x 1

Battery Life

Approx. 60 hours (continuous)

Consumed Current

Approx. 5mA

Diameter of Measurable Conductor

68mm maximum

Dimensions

Approx. 129mm (W) x 248mm (H) x 55mm (D)

Weight

Approx. 570g

Accessories

User's manual (IM CL360), Batteries & Carrying Case (93031)

 

Home | Amprobe | CIE | Fluke | Kyoritsu-Kew |Megger | Reed | Yokogawa | Site Map | Search

Leda Electronics Pty. Ltd.
A.C.N. 078 681 562           A.B.N. 83 078 681 562
                                                      14 Wright Street Kewdale, Western Australia 6105                                                            
Phone: 61 8 9472 4444          Fax: 61 8 9472 4644