Yokogawa CA310 Voltage/mA Process Calibrator

Yokogawa_logo_sml

The Yokogawa CA310 Process Calibrator simultaneously supplies a 24V loop power and measure output signal with an accuracy of accuracy 0.015%. The sub display shows value of voltage source and span %. The CA310 features step sweep, linear sweep, manual step and span check source patterns.

Features

  • CA310 Volt mA Calibrator:
    • 0.015% basic accuracy
    • 20mA SIMULATE (SINK) function
    • HART/BRAIN comm. resistance (250Ω) embedded
    • Segment LCD display
Authorised Australian Distributor

pdf-6    Yokogawa CA300 Series Datasheet

If you would like more information regarding this product, simply email us here.
  • This field is for validation purposes and should be left unchanged.
SKU: Yokogawa CA310 Categories: , Tags: , ,

The Yokogawa CA310 Voltage/mA Process Calibrator simultaneously supplies a 24V loop power and measure output signal with an accuracy of accuracy 0.015%. The sub display shows value of voltage source and span %. The CA310 features step sweep, linear sweep, manual step and span check source patterns.

Yokogawa CA310 Voltage/mA Process Calibrator Features:

  • CA310 Volt mA Calibrator:
    • 0.015% basic accuracy
    • 20mA SIMULATE (SINK) function
    • HART/BRAIN comm. resistance (250Ω) embedded
    • Segment LCD display
The Yokogawa CA310 is a Volt mA calibrator. The CA300 series process calibrator is a high accuracy source and measure portable handheld calibrator used to inspect and maintain the accuracy of control devices such as temperature controllers, temperature transmitters, temperature sensors and other process devices which are used in process plants, industry machinery and manufacturing. The CA310 voltage and current simulate model is capable to execute a loop check by simulating a transmitter, sinking the current signal from the external source. It achieves the high accuracy 0.015% of setting to source 4mA to 20mA. DC mA signals can be measured by supplying power to the transmitter from a 24V DC power supply. DC mA measurement and zero-point check can be performed with an accuracy of 0.015% of reading. A 250 ohm resistor for HART and BRAIN communication is included in this calibrator so there is no need to attach an external resistor when connecting to a handy terminal.
  • Sub display displays span% of the source value
  • Various types of source pattern such as step sweep/ linear sweep/ manual step/ span check
  • Operating temperature range from -10°C to 55°C
  • Dimension of 90mm (W) x 192mm (H) x 42mm (D)
  • EN61010-1 / EN61010-2-030 safety standard
  • Segment LCD display and LED backlight

Yokogawa CA310 Calibrator Source Specifications

DCV Range Source Range Accuracy Resolution
500 mV 0 to ±550.00 mV 0.015% of reading + 50 μV 10 μV
5 V 0 to ±5.5000 V 0.015% of reading+0.5mV 0.1 mV
30 V 0 to ±33.000 V 0.015% of reading+5 mV 1 mV
DCmA Range Source Range Accuracy Resolution
20 mA 0 to ±24.000 mA 0.015% of setting + 3 μA 1 μA
20 mA SIMULATE 0 to ±24.000 mA 0.015% of setting + 3 μA 1 μA

 

Yokogawa CA310 Calibrator Measuring Specifications

DCV Range Source Range Accuracy Resolution
500 mV 0 to +/-550.00 mV 0.15% of reading + 50μV 10 uV
5V 0 to +/-5.500 V 0.015% of reading + 0.5 mV 0.1 mV
30 V 0 to +/-33.0000 V 0.015% of reading+ 5 mV 1 mV
50 V 0 to 1.1000 V 0.015% of reading + 5 mV 1 mV
DCmA Range Source Range Accuracy Resolution
20 mA 0 to +/-24.000 mA 0.015% of reading +3μA 1 μA
50 mA 0 to +/-60.000 mA 0.015% of reading +3μA 1 μA

 

Yokogawa CA310 Calibrator General Specifications

Display: Segment LCD
Backlight: LED (Selection of “Constantly ON”, “Constantly OFF” or “Auto off by approx. 2min”)
Battery life: 50 hours (5V source, load over 10kOhm), 25 hours
(20mA source, load under 5V)
Automatic Power-off: Approximately 20 minutes (Can be disabled by setting)
Display Refresh Rate: Approx 1 sec.
Level Setting
Response of generator:
Approximately 1 second
(from when the output begins to change until when the output level falls within the specified accuracy)
Dimensions: Approximately Approx. 90 (W)×192 (H)×42 (D)
Weight: Approximately 440 g
Operating temperature/humidity: -10 to 55°C and 20 to 80%RH (no condensation)
Storage temperature: -20 to 60°C and 90%RH or less (no condensation